Measurements
After settings are checked/changed, press the READ key to obtain
moisture readings. The active settings appear briefly. Then, if the
measuring pads are not in contact with any material, the lowest pos-
sible value for the active material setting appears: SCAN/Min is 4.3%
for setting 160. If measurements are taken, the measured value
(9.6%), the active setting for material (160) and measuring depth
(1/4”) are displayed.
While taking measurements:
- If the material is too dry to be measured, the meter will show the lowest possible
value indicated by SCAN/Min on the left side of the display.
- If the material is too wet to be measured, the highest possible value is indicated by
SCAN/Max on the left side of the display.
To obtain accurate measurements:
Turn the meter on and place it on the test sample
(for wood in the direction of the grain). Press down
lightly, holding the outer sides of the meter without
touching the test sample with your hand. It is im-
portant to put light pressure on the meter towards
the test sample. For accurate measurements:
- The test sample should be big enough to cover both
measuring pads.
- The test sample should be at least as thick as the selected measuring depth. Page 13.
- If the surface is not smooth and flat, several measurements should be taken.
Select the highest value.
Note, all materials within the measuring field contribute to the value indicated. If the
test sample is composed of different materials, the value indicated may not be a true
moisture percentage, but may only be a reference number. It can be hard to find the
correct code number for engineered or composite materials. Page 15: Find Settings for
Composite and Engineered Boards.
To make sure the material underneath the test sample is not influencing the measure-
ments, arrange an air space underneath the test sample. For example: Elevate one end
of the test board to create an air space underneath the board. If this is not possible,
make sure the Ligno-VersaTec is set for the correct measuring depth.
Measuring veneer, page 15.
12