Hold Function for all Modes: Pin - Pinless - RH
The HOLD key is used (while taking readings) to “freeze” measured
values for three minutes. During that time you can switch back to
measuring by pressing the READ key again. This feature is helpful when
taking notes or when measuring in areas, where the display cannot be read.
Warranty: All Lignomat meters have a 2-year warranty.
Accessories have a 1-year warranty. Battery and pins are excluded.
Ligno-VersaTec, the Meter
BNC connector for:
- cable from electrode.
- adapter H for in-kiln cables.
% sign is only present, if
the indicated value is a
moisture percentage.
If % sign is missing,
the value is a reference
number.
Measured value.
For measurements in
pin, pinless or RH mode,
press the READ key.
Two measuring pads are
mounted on the back of the
meter. The measuring pads
cover an area of:
2.75” L x 1.75” W
(6.8 x 4.2 cm)
Overall size of Meter:
4.5” x 2.4” x 1”
(12 x 6 x 2.5 cm)
If the display is blank and
the SET/HOLD key is
pressed repeatedly,
active settings are displayed:
- pin or scan mode.
- wood or material setting.
- wood temperature (pin).
- measuring depth (pinless).
If the display shows a
measured value and the
SET/HOLD key is pressed
repeatedly, the meter is put
into HOLD mode first.
Then, the active settings are
recalled. See above.
Press up or down key
to change settings.
Battery cover is located
at the back of the meter.
Battery: One 9V battery.
A low battery symbol will
appear on the display,
when the battery is
drained to 25%.
5
3.5mm Stereo connector
for RH BluePeg using
- RH Adapter.
- RH cable.
Once the RH probe is
connected, the meter
switches automatically
into RH mode.
Press up or down key
to change settings.
The up or down key can
also be used to change
depth settings in pinless
mode while taking mea-
surements. Toggle mode.
Page 14.