Linde HPR-2 Specifications

General IconGeneral
BrandLinde
ModelHPR-2
CategoryWater Pump
LanguageEnglish

Summary

General technical data.

Overview of technical data

Presents key technical specifications for the HPR-02 pump across various rated sizes.

General technical data. (cont.)

Selection diagram

Graphical representation for selecting appropriate HPR-02 pump models based on input speed and volume flow.

Operational parameters. Life time recommendations

Life time recommendations

Provides guidance on beneficial and adverse factors affecting the service life of high pressure units.

Operational parameters. Pressure fluids

Permitted pressure fluids

Lists approved types of hydraulic fluids, including mineral oils and biodegradable options.

Recommended viscosity ranges

Provides recommended viscosity ranges for hydraulic fluids based on operating temperature.

Linde LSC-System.

Functionality

Explains the demand-oriented pump control and precision characteristics of the LSC-System.

Benefits

Highlights advantages such as optimized energy balance, dynamic machine control, and reliability.

Noise reduction. SPU silencer

Pressure pulsations with and without SPU

Compares pressure pulsation levels in hydraulic systems with and without the SPU silencer.

Noise reduction. SPU silencer (cont.)

SPU silencer function

Describes the SPU silencer's function in reducing pressure pulsations and noise emission.

Comparison of sound pressure levels for a HPR 75-02 pump with and without SPU

Presents comparative sound pressure level data for pumps with and without SPU.

Comparison of resulting noise emission

Illustrates noise emission differences between conventional and SPU-equipped pumps.

Torque transmission. Mounting flange

Mounting flange dimensions and torque

Specifies torque, screw, and dimensional data for different SAE mounting flanges.

Torque transmission. PTO through drive

B) Dimensions PTO

Specifies PTO dimensions, including drive hub profile, spigot diameter, and bearing clearance.

Torque transmission. PTO flange and output shaft

B) Output shaft transfer torque

Details continuous and maximum transfer torque ratings for output shafts.

Controllers.

Technical data

Provides a table of technical data for various controller types and their functions.

Controllers. LS. Load Sensing

Load Sensing. Flow on demand control

Explains how load sensing controls pump flow based on system demand.

Benefits of LS-control

Lists advantages of LS control such as precise control and reduced energy consumption.

Demand-oriented pump control offers the following benefits

Highlights benefits of demand-oriented control like load independence and increased pump life.

Controllers. LP. Load Sensing with hydraulic pressure cut-off

LP. LS with hydraulic pressure cut-off

Describes the LP controller's function for load sensing with hydraulic pressure limitation.

LP-characteristic curve

Illustrates the characteristic curve of the LP controller, showing pressure cut-off.

Controllers. E1L/H1L. Load Sensing with electric / hydraulic override

Possible applications of the LS signal override

Explains mode control and power limit regulation using LS signal override.

E1L/H1L-characteristic curve

Presents the characteristic curve for E1L/H1L controllers.

Controllers. E1L. Load Sensing with electric override

Controllers. H1L. Load Sensing with hydraulic override

Ap LS-reduction

Diagram showing Ap LS reduction based on pilot pressure for H1L controller.

Controllers. Electrical properties

E1L-controller electrical characteristics

Details electrical properties for the E1L controller, including supply voltage and connector type.

Controllers. TL2. Load Sensing with hyperbolic power limitation

TL2. LS with hyperbolic power limitation

Explains the TL2 controller's load sensing and hyperbolic power limitation.

Controllers. LEP. Load Sensing with electro-proportional flow limitation and pressure cut-off

Controllers. ETP. Electro-proportional flow setting, power limitation and pressure cut-off