EasyManua.ls Logo

Linksys SPA1001

Linksys SPA1001
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-16
Linksys ATA Administrator Guide
Document Version 3.1
Chapter 3 Configuring Linksys ATAs
Using a FAX Machine with the SPA2102 or SPA8000
Step 1 Upgrade the ATA firmware to the latest version
Step 2 Ensure that you have enough bandwidth for uplink and downlink.
For G.711 fallback, it is recommend to have ~100Kbps.
For T.38, allocate at least 50 kbps.
Step 3 To optimize G.711 fallback fax completion rates, use the following settings on the Line tab of the
Linksys ATA:
Network Jitter Buffer: very high
Jitter buffer adjustment: disable
Call Waiting: no
3 Way Calling: no
Echo Canceller: no
Silence suppression: no
Preferred Codec: G.711
Use pref. codec only: yes
Step 4 If you are using a Cisco media gateway for PSTN termination, disable T.38 (fax relay) and enable fax
using modem passthrough.
For example:
modem passthrough nse payload-type 110 codec g711ulaw
fax rate disable
fax protocol pass-through g711ulaw
Step 5 Enable T.38 fax on the SPA 2102 by configuring the following parameter on the Line tab for the FXS
port to which the FAX machine is connected:
FAX_Passthru_Method: ReINVITE
Note If a T.38 call cannot be set-up, then the call should automatically revert to G.711 fallback.
Step 6 If you are using a Cisco media gateway use the following settings:
Make sure the Cisco gateway is correctly configured for T.38 with the SPA dial peer. For example:
fax protocol T38
fax rate voice
fax-relay ecm disable
fax nsf 000000
no vad
Troubleshooting
If have problems sending or receiving faxes, complete the following steps:
Step 1 Send a test Fax in a controlled environment between two Linksys ATAs.
Step 2 Determine the success rate.
Step 3 Monitor the network and record the following statistics:
Jitter