EasyManua.ls Logo

Linksys SPA922

Linksys SPA922
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Linksys SPA9x2 Phone Administration Guide 66
Advanced Scripting for Cadences, Call Progress Tones, and Ring Tones
Setting Regional Parameters
A RingScript is a mini-script that describes a ring tone. The syntax follows:
•n=ring-tone-name;w=waveform-id-or-path;c=cadence-id;b=break-time;t=total-time
ring-tone-name is a name to identify this ring tone specification. This name will appear
on the Ring Tone menu of the phone. The same name can be used in a SIP Alert-Info
header in an inbound INVITE request to tell the phone to play the corresponding ring
tone specification. Because of this, the name should contain characters allowed in a URL
only.
Waveform-id is the index of the desired waveform to use in this ring tone specification.
There are 4 built-in waveforms:
1 = A classic phone with mechanical bell
2 = Typical phone ring
3 = A classic ring tone
4 = A wide-band frequency sweep signal
This field can also be a network path (url) to download a ring tone data file from a server
on-the-fly. In this case, the syntax of the field is
w=[tftp://]hostname[:port]/path.
cadence-id is the index of the desired cadence to play the given waveform. 8 cadences
(1–8) as defined in <Cadence 1> through <Cadence 8>. Cadence-id can be 0 If w=3,4, or
an url. Setting c=0 implies the on-time is the natural length of the ring tone file.
Example 3: SIT Tone
985@-16,1428@-16,1777@-16;20(.380/0/1,.380/0/2,.380/0/
3,0/4/0)
Number of Frequencies = 3
Frequency 1 = 985 Hz at –16 dBm
Frequency 2 = 1428 Hz at –16 dBm
Frequency 3 = 1777 Hz at –16 dBm
Number of Cadence Sections = 1
Cadence Section 1: Section Length = 20s
Number of Segments = 4
Segment 1: On=0.38s, Off=0s, with Frequency 1
Segment 2: On=0.38s, Off=0s, with Frequency 2
Segment 3: On=0.38s, Off=0s, with Frequency 3
Segment 4: On=0s, Off=4s, with no frequency components
Total Tone Length = 20s

Table of Contents

Other manuals for Linksys SPA922

Related product manuals