Rev: 06.25.20 Page 11 CCD-0001515
Troubleshooting Table
What Is Happening? Why? What Should Be Done?
System will not turn on
and ON/OFF indicator
light does not illuminate.
Coach ignition not in RUN
position.
Turn ignition to RUN position.
Parking brake not set. Set parking brake.
Controls have been on for
more than four minutes
and have timed out.
Turn ignition off and then back on.
Touchpad turns on,
but turns off when jack
button is pushed.
Low voltage on battery. Start coach to charge battery.
Touchpad turns on,
coach will not auto level,
JACKS DOWN light is on,
jacks are retracted.
Faulty pressure switch or
low pressure in system.
Press RETRACT ALL JACKS button on touchpad. If JACKS
DOWN light remains on, call LCI Customer Service.
Jacks will not extend
to ground, pump is
running.
Little or no fluid in
reservoir.
Fill reservoir with recommended ATF.
Jack valve is inoperative. Clean, repair or replace.
Electronic signal is lost
between controller and jack
valves.
Trace wires for voltage drop or loss of signal. Repair or
replace necessary wires or replace controller.
Any one or two jacks will
not retract.
Hose damaged or
disconnected.
Replace with new hose or reconnect hose.
Return valve inoperative. Replace inoperative return valve.
Electronic signal is lost
between controller and
solenoid.
Test for voltage drop between controller and jack valve.
Repair bad wiring or replace defective controller or
valve.
JACKS DOWN light does
not go out when all jacks
are retracted.
Insufficent pressure in
system.
Contact LCI Customer Service.
Retract pressure switch
inoperable.
Check connection or replace.
Alarm sounds and
JACKS DOWN light starts
flashing while traveling;
jacks are fully retracted.
Loss of pressure in leveling
system.
Contact LCI Customer Service.
Retract pressure switch
inoperable.
Check connection or replace.
Jack bleeds down after
being extended.
Valve Manual Override
open.
Close override.
Touchpad powers up;
LOW VOLTAGE light
flashes.
Engine not running. Start coach engine.
Low voltage light on
solid.
Charging system faulty.
Turn key OFF, then back ON again to reset. Check power
and ground connections on battery, alternator and
chassis.
No power to touchpad.
Tripped circuit breaker. Reset breaker.
Ignition not on. Turn on.