  • E
    Eric HessSep 8, 2025
    What to do if any one or two jacks will not retract on Lippert Components Level-Up Lifting Systems?
    • S
      Steven KeySep 8, 2025
      If one or two jacks will not retract, consider the following: * A hose may be damaged or unconnected. Replace with a new hose or reconnect the existing one. * A valve may be inoperative. Replace the inoperative valve. * An electronic signal may be lost between the controller and the solenoid. Attempt to retract the jacks in MANUAL mode. If successful, replace the touch pad; if not, test for voltage drop between the touch pad and the valve, repair any bad wiring, or replace the defective board or valve.
  • H
    Heather McintoshAug 25, 2025
    What to do if Lippert Components Lifting Systems shows 'Auto Level Fail' error?
    • T
      Tiffany MarshallAug 25, 2025
      If your Lippert Components Lifting Systems displays an 'Auto Level Fail' error, it could be due to uneven ground or an incorrectly set zero point. Check the position of the jacks and consider relocating the trailer to more level ground. If the ground isn't the issue, reset the zero point.
  • J
    juarezmichaelAug 25, 2025
    What to do if Lippert Components Level-Up Lifting Systems displays 'Out Of Stroke' error?
    • J
      James GreenAug 26, 2025
      If your Lippert Components Lifting Systems displays an 'Out Of Stroke' error, it means the jack has reached its maximum stroke length and can't lift any further. Check the disposition of the jacks and/or relocate the trailer.
  • I
    ijosephSep 18, 2025
    What does 'Comm Error' mean on Lippert Components Level-Up Lifting Systems and how can I resolve it?
    • K
      krogersSep 18, 2025
      If the Lippert Components Lifting Systems display a 'Comm Error', it means communication between the controller and touch pad has been lost. Check the harness for proper connections or damage, and replace it if necessary.
  • N
    Nathan GlennSep 8, 2025
    What to do if Lippert Components Level-Up system will not turn on and on/off; indicator light does not illuminate?
    • M
      Melissa SmithSep 8, 2025
      If the system will not turn on and the on/off indicator light does not illuminate, check the following: * Ensure the coach ignition is in the RUN position. If not, turn the ignition to the RUN position. * If the controls have been on for more than four minutes, they may have timed out. Turn the ignition OFF and then back ON.
  • C
    Connor OdonnellSep 12, 2025
    What causes 'AUTO LEVEL FAILURE' in Lippert Components Tools and how to fix it?
    • Z
      Zachary WestSep 12, 2025
      An 'AUTO LEVEL FAILURE' in Lippert Components Tools can be caused by an unsecured controller or a voltage drop. Make sure the controller placement is secure. Also, test the battery voltage under load and charge or replace the battery if necessary.
  • F
    fdunnSep 3, 2025
    What does 'INTERNAL SENSOR' mean on Lippert Components Level-Up?
    • W
      washingtondarleneSep 3, 2025
      If your Lippert Components Lifting Systems displays 'INTERNAL SENSOR', it indicates there is a problem with the internal sensor. The suggested solution is to replace the controller.
  • S
    sarahrossSep 3, 2025
    How to fix 'EXTERNAL SENSOR' error on Lippert Components Level-Up Lifting Systems?
    • H
      Holly WhiteSep 3, 2025
      If your Lippert Components Lifting Systems displays 'EXTERNAL SENSOR', it indicates a bad connection or wiring from the controller to the sensor. To resolve this, replace or repair the connection to the rear remote sensor.
  • C
    Carolyn StanleySep 23, 2025
    What does 'External Sensor' error mean on Lippert Components Level-Up?
    • V
      Vincent MillerSep 23, 2025
      If the Lippert Components Lifting Systems display an 'External Sensor' error, it indicates a bad connection or wiring from the controller to the rear sensor. Replace or repair the connection to the rear remote sensor.
  • A
    Amy MendezAug 29, 2025
    Why Lippert Components Lifting Systems shows 'Panic Stop Function Aborted'?
    • R
      Renee SilvaAug 29, 2025
      The 'Panic Stop Function Aborted' error on your Lippert Components Lifting Systems means a button was pressed on the touch pad during an automatic operation. Restart the automatic operation and refrain from pressing any buttons on the touch pad.

Summary

System

Prior to Operation

Conditions and steps required before operating the leveling system.

System Description

Component Description

Maintenance

Fluid Recommendation

Details on recommended hydraulic fluid type and usage.

Preventative Maintenance

Schedule and steps for routine system maintenance.

Fitting Orientation

Controls

Features

System Wiring Requirements

Air and Auxiliary Features

Level Zero Point Calibration

Error Mode

Excess Slope

User Alarm Mode

Miscellaneous Operations

Low Voltage Signal

Operation

Selecting A Site

Guidance on choosing a suitable location for leveling.

Automatic Leveling Procedure

Step-by-step instructions for automatic leveling.

Automatic Leveling Logic

Manual Leveling Procedure

Jack Retract Procedures

Remote Leveling Operation

Manual Override - Jacks

Manual Override - Power System

Automatic Safety Shutoff

Drive Away Protection System

Jacks Down Alarm

Fluid Specification Details

Wiring Diagram

Plumbing Diagram

Bill of Materials

Troubleshooting Guide

Level-Up Motorized Leveling System Components

Leveling Jacks and Footpads

Diagrams of leveling jacks, footpads, and associated components.

Hydraulic Power Unit

Diagrams of the hydraulic power unit and its key parts.

Control System Components

Diagrams of controller, touch pad, sensors, and harnesses.

Lippert Components Level-Up Specifications

General IconGeneral
System TypeAutomatic Hydraulic
CategoryLifting Systems
Number of Jacks4 or 6
Auto-LevelingYes
Manual OverrideYes
Power Source12V DC
Control TypeElectronic
Installation TypeFrame-mounted

Related product manuals