47
SPECIFICATIONS
Data isn’t transferring to ProWeatherLive. 1. In the console SETUP page, ensure your Station ID
and Station Key are correct.
2. In the “Edit Devices” of the console on PWL, ensure
the device’s Mac address is entered correctly.
Rainfall data is not correct. 1. Make sure the rain collector is clean for the tipping
bucket to tip smoothly.
2. Make sure the sensor has stable and level to ensure
correct tipping.
The temperature is too high in the daytime. 1. Place the sensor in an open area and at least 4.9’
(1.5 m) o the ground.
2. Ensure that the sensor is placed away from heat-
generating sources or structures, such as buildings,
pavement, walls, or air conditioning units.
Some condensation beneath the UV sensor may occur
overnight.
This will disappear when the temperature rises up under
the sun and will not aect the performance of the unit.
Console is not responding. 1. Remove backup battery.
2. Unplug AC adapter.
3. Wait a minute.
4. Insert backup battery and plug in AC adapter.
GENERAL SPECIFICATIONS
Product type: Weather/environment sensor & console
Dimensions (W x H x D): 8.5″ x 6″ x 0.9″ (217 x 152.5 x 23.5 mm) (without
kickstand extended)
Weight: 1.2 lbs. (552 g) (with battery)
Power source: DC 5 V, 1 A adapter
Backup battery: CR2032
Operating temperature environment: 23 °F - 122 °F (-5 °C - 50 °C)
Adult assembly required for console: No No
Location use for console: Indoor use
Additional tools required for console: No
Country of origin: China
Warranty included: Yes