Logitek
Appendix B
Specifications
Appendix B Specifications
Artisan Frames
MLX-F24 (24 slot frame)
Dimensions 34.0” W x 18.4” D (864 mm x 467 mm)
MLX-F32 (32 slot frame)
Dimensions 45.2” W x 18.4” D (1148 mm x 467 mm)
MLX-F42 (42 slot frame)
Dimensions 59.2” W x 18.4” D (1504 mm x 467 mm)
Artisan Modules
Fader Module (MTK-FADER)
Width 2 slots
No of faders 2
Features The Fader Module provides the following features:
RGB-illuminated on/start button
Penny & Giles® conductive plastic faders with soft rubber caps
2 dedicated Aux bus sends with gain control and Ring of Fire level indicator
Direct assignment buttons for 2 Master and 4 Sub-Master busses, with menu access to a
further 4 Sub-Master busses
Dedicated controls for default/last input selection, talkback insertion and PFL bus
LCD screen and two rotary controls allow access to the input router control, input mode
control, input delay time, input trim level, pan/balance control, additional bus assigns, 4-
band equalizer and dynamics processor
Color LCD screen also displays input meters (stereo & 5.1) and a 16-character source name
Monitor Module (MTK-MON)
Width 2 slots
Features The Monitor Module provides the following features:
In-built XLR jack for talkback microphone
Gain controls for talkback in & out, two studio & control room monitor, plus cue speaker
Four direct talkback locations with mute & conference control
Talkback to studio monitor outputs
Four source selection hotkey buttons for input routing for Offline Source, Studio 1 monitor,
Studio 2 monitor and Control Room monitor
Full input routing capability on Studio 1 monitor, Studio monitor, Control Room monitor &
Switched Meter.
Full color LCD screen displaying 16-character source names for monitoring destinations
Ring of Fire LEDs indicate level for monitoring destinations
Logitek Artisan Reference Manual