Description Default Profile Range/Option Your requirement
Standard Alarm Parameters
Upper Alarm
Alarm direction upper upper Upper
Trigger this alarm disabled enabled or disabled
Temperature threshold value
3
- -25°C to 60°C (-13°F to 140°F)
Alarm activation type
4
instant instant, accumulative or consecutive
Activation delay time - 1 minute to 45 days
Lower Alarm
Alarm direction Lower Lower Lower
Trigger this alarm disabled enabled or disabled
Temperature threshold value - -25°C to 60°C (-13°F to 140°F)
Alarm activation type instant instant, accumulative or consecutive
Activation delay time - 1 minute to 45 days
Multi-AlarmParameters
5
Alarm 3
Alarm direction - upper or lower
Trigger this alarm disabled enabled or disabled
Temperature threshold value - -25°C to 60°C (-13°F to 140°F)
Alarm activation type instant instant, accumulative or consecutive
Activation delay time - 1 minute to 45 days
Alarm 4
Alarm direction - upper or lower
Trigger this alarm disabled enabled or disabled
Temperature threshold value - -25°C to 60°C (-13°F to 140°F)
Alarm activation type instant instant, accumulative or consecutive
Activation delay time - 1 minute to 45 days
Alarm 5
Alarm direction - upper or lower
Trigger this alarm disabled enabled or disabled
Temperature threshold value - -25°C to 60°C (-13°F to 140°F)
Alarm activation type instant instant, accumulative or consecutive
Activation delay time - 1 minute to 45 days
Alarm 6
Alarm direction - upper or lower
Trigger this alarm disabled enabled or disabled
Temperature threshold value - -25°C to 60°C (-13°F to 140°F)
Alarm activation type instant instant, accumulative or consecutive
Activation delay time - 1 minute to 45 days
For rules regarding setting up multiple alarms please see Alarm Configuration Options on page 1.
3
Upper value must be above lower value
4
l Instant = one temperature reading is above (below) the threshold
l Consecutive = temperature readings are above (below) the threshold for the time defined in the activation delay without interruption
l Accumulative = temperature readings are above (below) the threshold for the total time defined in the activation delay time, but may not necessarily be sequential.
5
Only on model "M" with multiple alarms.
Page 15 of 16 UTRIX-16(M) Product User Guide, Revision 2.0, copyright © 2004-2016, LogTag
®
Recorders . All rights reserved.