5. Operating the Unique 2.1
The following Profile settings can be adjusted:
1. Pause (Pre-Runtime) 0 - 99 min
2. Pump (Level A) 1 - 99 %
3. Fan (Level A) 1 - 99 %
4. Run-Time (Level A) 0 - 99 min
5. Pump (Level B) 1 - 99 %
6. Fan (Level B) 1 - 99 %
7. Run-Time (Level B) 0 - 99 min
With the HDCS, an individual profile for a show can be programmed. Two Levels (Level
A and B) with different pump and fan values and different run-times can be program-
med (Level A = settings 2, 3, 4 / Level B = settings 5, 6, 7). Also a pre-runtime can be
programmed in (setting 1) which tells the machine when it should start to run.
For example: The machine shall start to run after 30 Minutes (setting 1). Then the
stage should be filled with haze within 10 Minutes. Therefore a high pump and fan
output should be adjusted and a time of 10 Minutes (setting 2, 3, 4). After 10 Minutes
high output, pump and fan shall go down automatically to a lower step and fill the
stage with haze for another hour (setting 5, 6, 7). See diagram on page 15 also.
a) Press the Mode button repeatedly [14], until „Pro“ appears on the display (see Fig.
4).
b) Press the Enter button [16] once to switch to the HDCS Menu. The red Timer/Profile-
LED [20] will be lit.
c) Adjust settings 1 to 7 according to the chart on page 15, using the Up/Down buttons
[15] and pressing the Mode button to switch between the settings.
These settings are stored in non-volatile memory. You don‘t have to run the Profile
or press the Enter button in order to „save“ the settings. All settings can be changed
as described at any time.
d) To start the Profile with the adjusted values, press the Mode button [14], until „run“
appears on the display (Fig. 8), then press the Enter button [16].
The Timer/Profile-LED [20] flashes, indicating that the Profile is running. The green
Active-LED [18] lights as soon as the adjusted Pause (Pre-Runtime) has passed and
level A has started. The Profile can also be started via an optional radio remote.
e) To leave the HDCS menu or quit the Profile, first press the Mode button until „ESC“
appears on the display (Fig. 9). Then press the Enter button [16] once to return to
the main menu.
5.4.4.1 Using the Profile