    Michael GonzalezJul 29, 2025
    What to do if Look Solutions Fog Machine pump runs but no haze is produced?
    • B
      Brittany TaylorJul 30, 2025
      If the pump of your Look Solutions Fog Machine is running, but little to no haze is being produced, it may be due to the pump not sucking enough fluid. Here are some things to check: * Make sure the canister is not empty. * Verify the brass collar is properly connected to the brass coupling. * See if the fluid filter in the canister is clogged. * Inspect the fluid tube for twists or defects.
  • E
    Edward RobertsAug 6, 2025
    What to do if E-4 appears on Look Solutions Fog Machine LED display?
    • U
      ujohnsonAug 6, 2025
      If 'E-4' appears on the LED display of your Look Solutions Fog Machine, it indicates that the machine is overheating. The heating will switch off, and the machine will cool down. To address this, disconnect the machine from the mains supply for a moment and then reconnect it.
  • L
    laradeniseAug 13, 2025
    Why yellow LED doesn't light up on Look Solutions Fog Machine when running via DMX?
    • L
      Lindsay BullockAug 13, 2025
      If the yellow LED on your Look Solutions Fog Machine does not light up when running via DMX, the connection from the machine to the desk may be faulty. To resolve this: * Ensure the plug is correctly plugged in. * Check the cable for any defects. * Confirm that the DMX start address is adjusted correctly.
  • J
    johnfordAug 20, 2025
    Why does Look Solutions Fog Machine Unique fail to work for a long time?
    • J
      Jesus JordanAug 20, 2025
      If your Look Solutions Fog Machine Unique fails to work for a long time during operation, the overtemperature protection device may be activated. Check whether the fan is clogged.

Summary

Safety instructions

Fluid

Operating the Unique²

DMX 512 Control

Instructions for controlling the Unique² haze machine using DMX 512.

Cleaning, Care and Maintenance

Troubleshooting

No Haze Output Issues

Troubleshoots scenarios where the pump runs but no haze is produced.

Error Code E-4: Overheating

Guidance for resolving the E-4 error code related to excessive heat.

Error Code E-8: Vaporizer Clogging

Instructions for the E-8 error code indicating a clogged vaporizer.

Error Code E-1: Service Required

Procedure for the E-1 error code, indicating the need for professional service.