6. Cleaning, Care and Maintenance
Remove the filter, which protects the fan against dust and dirt, from time to
time and clean it.
After several hours of operation, some droplets of condensation will have
formed at the nozzle. That is normal and not a malfunction.
Please note: Remove fluid droplets at the nozzle only when the machine has
completely cooled off. During operation the nozzle gets very hot!
Do not let the Unique
2
run without any fluid as the pump will run dry.
Check the state of the fluid filter [12] from time to time and clean or replace it
when necessary.
PLEASE NOTE: The vaporizer of our machines does not have to be cleaned!
Cleaners, available on the market, can damage the vaporizer! We cannot grant
warranty in this case.
Trouble: The pump runs, but little or no haze is produced.
Cause: The pump sucks no or too little fluid.
· Check whether the canister is empty
· Check whether the brass collar is properly connected with the brass
coupling
· Check whether the fluid filter in the canister is clogged
· Check whether the fluid tube is twisted or defective
Trouble: The yellow LED at the machine does not light up (when running
via DMX)
Cause: Connection from the machine to the desk is faulty.
· Check whether the plug is plugged in correctly
· Check whether the cable is defective
· Check whether the DMX start address is adjusted correctly
Trouble: During operation the Unique
2
fails to work for a long time
Cause: The overtemperature protection device is activated.
· Check whether the fan is clogged
7. Troubleshooting