Chapter 7. Usage of Various Functions
7-81
(2) Speed Control (Uniform Speed Operation)
This controls the speed by the setting speed until deceleration stop command(POSCTR) is entered after execution by
POSVEL command..
The speed can be changed by the speed override instruction(POSSOR)
Speed control contains 2 types of start method : Forward direction start and Reverse direction start.
- Forward direction : when position address is positive number (+) (“0” included)
- Reverse direction : when position address is negative number (-)
Forward direction Reverse direction
Set second operand of POSVEL instruction to 0
Set second operand of POSVEL instruction to 1
Timing diagram
Please refer to the section ‘POSVEL’ for details.
(3) Synchronization control
After the execution of POSSYNC, the HSC input pulse speed is synchronized by the designated synchronization
scale.
Scale can be changed during the execution.
Setting range: 0 ~ 100%
Speed
On
Time
On
Setting speed
Dwell time
Deceleration stop command
(POSCTR)
Speed control command
(POSVEL)
REMARK
Scale =
Positioning speed
HSC input speed