12.9 Configuring HDD Error Alarms
Purpose:
You can configure the HDD error alarms when the HDD status is Uninitialized or Abnormal.
Steps:
1. Enter the Exception interface.
Menu > Configuration > Exceptions
2. Select the Exception Type to HDD Error from the dropdown list.
3. Click the checkbox(s) below to select the HDD error alarm type (s), as shown in Figure 12. 29.
The alarm type can be selected to: Audible Warning, Notify Surveillance Center, Send Email and Trigger Alarm
Output. Please refer to Chapter Setting Alarm Response Actions.