1KVA/ 2KVA/ 3KVA
INVERTER / CHARGER
User Manual

Questions and Answers

  • R
    Rickey PorterAug 8, 2025
    What to do if my Luminous 2KVA is beeping continuously and the red LED is on?
    • C
      Catherine PerezAug 8, 2025
      A continuous beep and a red LED on your Luminous Inverter usually indicates a problem. This could be due to several reasons: * The inverter might be overloaded (more than 110% load). Try reducing the load by switching off some equipment. * There may be a short circuit in the output. Check the wiring and remove any unusual loads. * The internal converter component's temperature might be too high (over 120°C). Ensure the unit's airflow isn't blocked and the ambient temperature isn't too high. * The battery voltage may be too high. Verify that the battery specifications and quantity meet the requirements. If none of these steps resolve the issue, it may be necessary to return the inverter to a repair center.
  • B
    Brenda HansonAug 14, 2025
    Why does my Luminous Inverter work in battery mode even when mains exist?
    • J
      Julie JohnsonAug 14, 2025
      If your Luminous Inverter continues to operate on battery power despite the availability of mains power, there are a few potential causes: * The input protector might be tripped. Check if the AC breaker has tripped and ensure the AC wiring is properly connected. * The quality of the AC power (from shore or generator) may be insufficient. Check if the AC wires are too thin or too long. * The solar power may be set as the priority output source. Change the output source priority to 'Utility first'.
  • J
    Joshua BarnesAug 20, 2025
    What to do if Luminous Inverter shuts down automatically during startup?
    • B
      brittany46Aug 21, 2025
      If your Luminous Inverter shuts down automatically during startup, it could be due to the following reasons: * The battery voltage is too low (less than 1.91V/Cell). Try recharging the battery. * The battery might need to be replaced.
  • M
    murphyalexAug 27, 2025
    What to do if there is no response after powering on my Luminous 2KVA?
    • J
      Jonathan FrancisAug 27, 2025
      If your Luminous Inverter doesn't respond after you power it on, consider these potential causes: * The battery voltage might be extremely low (less than 1.4V/Cell). Check the connections of the batteries and wiring to make sure they are well connected. * The battery polarity may be connected in reverse. Recharge the battery. * The battery might need replacement.
  • R
    Rebecca BeckSep 2, 2025
    What to do if the internal relay of my Luminous 2KVA Inverter is switching on and off repeatedly?
    • V
      Victor WilliamsSep 2, 2025
      If the internal relay of your Luminous Inverter is repeatedly switching on and off when you turn it on, it might be due to a disconnected battery. Check the battery wires to ensure they are properly connected.

Summary

Safety Instructions

Operation Diagrams and Working Conditions

Installation

Unpacking and Inspection

Details items received in the package and checks for damage before installation.

Mounting the Unit

Guidelines for selecting an installation location and ensuring proper clearance and ventilation.

Battery Connection

AC Input;Output Connection

PV Connection

Operation

Power ON;OFF

Instructions on how to turn the unit on and off using the switch.

Operation and Display Panel

Describes the front panel components including indicators, function keys, and LCD display.

LCD Setting

Operating Mode Description

Fault Reference Code

Warning Indicator

Specifications

Trouble Shooting

Luminous 2KVA Specifications

General IconGeneral
Capacity2 KVA
CoolingFan Cooled
Battery Voltage24V
Frequency50Hz
ProtectionOverload, Short Circuit, Deep Discharge
WaveformPure Sine Wave