CDA3000 Operation Manual
4-17
4 Commissioning
DE
EN
FR
IT
ES
FR
1
2
3
4
5
A
CARD MENU Read from/write to SMARTCARD:
In this menu inverter settings can be saved to the SMARTCARD and
transferred to other inverter modules.
In every storage operation all parameters are always saved to the
S
MARTCARD. For read operations, either all parameters or only
parameters from one subject area (per read operation) can be
read-in.
For more information on operation with the KEYPAD refer to the KEYPAD
KP200 Operation Manual.
Function Meaning
READ > ALL Read all parameters from SMARTCARD
READ > _27RS
Parameters from subject area,
e.g. B. _27RS (reference structure)
WRITE Store all parameters on the SMARTCARD
LOCK Write-protect the SMARTCARD
UNLOCK Cancel the write protection