CDD3000-HF Operation Manual
3-9
3  Installation
DE
EN
FR
IT
ES
FR
1
2
3
4
5
A
Connection The resolver is connected via plug connection X6 to the CDD3000-HF.
Figure 3.4 Resolver cable
Plug Connector A (drive controller):D-Sub 9-pin plug, metal housing
Connector B (motor): custom, to motor manufacturer's specification 
(for LUST servomotors: signal plug, 12-pin 
socket, e.g. Interconnectron type PLD 121 NV 
171187)
Cable type Cable festoon compatible, e.g. Intercond 3MYI 17Z 10P (4x2x0.25 mm² +
2x1 mm²) or Lapp Unitronic FD CP TP (3x2x0.25 mm²) with UL approval.
Pin assignment You can enter your custom assignment in the columns for connector B.
Sinus/Cosinus encoder
With the drive controller the following rotary encoders can be evaluated:
A
B
Connector A Function Connector B Wire colour
CDD3000-HF-X6
Custom
1SIN+   (S2)
2SIN-    (S4)
3 COS+  (S1)
4GND
5
6
REF+   (R1)
(8 kHz, approx. 7 V AC)
7 REF-    (R2) (GND)
8COS-  (S3)
9
Outer shield on housing
Table 3.4 Resolver cable pin assignment