5-4
CDD3000-HF Operation Manual
5 Diagnosis/Fault rectification
5.4 Resetting errors Resetting errors with response number 1 to 4 (WRN-LOCKS):
In control via terminals: rising edge at input ENPO
(attention: control is shut off!)
or:
with input Ixxx, to which the
function FIxxx = RSERR (Reset
Error) is assigned
In control via KeyPad: press stop/return key on KeyPad for
approx. 3 seconds
In control via D
RIVEMANAGER: click on “Reset error” button
In control via fieldbus: set “Reset error” bit in bus control
word
Starting the drive after an error Cancel start signal and reapply it.
With programmed auto-start function:
In error responses 1 and 2 the drive automatically restarts when
the error is reset.
In error responses 3 and 4 the drive does not restart until the
start signal has been withdrawn and re-sent.
Resetting errors with response number 5 (RESET):
Errors with response number 5 (RESET) are serious device errors. They
can only be reset by switching all supply voltages (mains, possibly 24V)
off and back on again.
Resetting errors (after
eliminating the cause)

Related product manuals