A-8
CDD3000-HF Operation Manual
 
A.2 Ambient 
conditions
 
Characteristic drive controller
Temperature 
range
in operation
-10 ...45 °C (BG1 ... BG5)
with power reduction to 55 °C
in storage -25 ... +55 °C
in transit -25 ... +70 °C
Relative air humidity 15 ... 85 %, condensation not permitted
Mechanical 
strength to 
IEC 68-2-6
Vibration
0.075 mm in frequency range 10 ... 57 Hz
1 g in frequency range 57 ... 150 Hz
Protection
Device IP20 (NEMA 1)
Cooling 
method
Cold plate: IP20
Push-through heat sink: IP54 (3 ...15 kW)
Touch protection VBG 4
Mounting height
up to 1000 m above MSL, above 1000 m above MSL 
with power reduction 1% per 100 m,  max. 2000 m 
above MSL
max. holding brake current 2 A to T
U
 = 45°C,
derating 50 mA/°C to T
Umax
 = 55°C
Voltage stress of the 
motor winding
typical slew rate 3 - 6 kV/µs