EasyManua.ls Logo

Lutron Electronics Grafik Eye GRX-4000 Series - Link B and DMX Control Wiring

Lutron Electronics Grafik Eye GRX-4000 Series
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step by Step Instructions for GRAFIK Eye Dimming Panel
7
SELECT CIRCUIT
2
1
Circuit
Data A OK
Power
1234 5D
Common
24VFW
MUX
MUX
Drain
Sense
1234
D
5
Data B OK
B
Comm
Drain
MUX
MUX
C
D
Link
A
Link
C
D
C
1
+
3
2
4
5
STAGEBOARD
RECEPTACLE
STEP 3: Control Wiring (continued)
Control Wiring for
DMX
3
434
OUT
IN
SSA
SSARET
2
1
STAGEBOARD
RECEPTACLE
All five wires are available in one cable from Lutron
(P/N GRX-CBL-46L).
To additional Control Units,
Wallstations, Panels, or Control
Interfaces
To panels where Link B
controls circuits. A Lutron
LT1 (Link Terminator)
should be used to terminate
Link B at the last panel.
DMX512 Stageboard on Link B
Cable recommended by Stageboard
manufacturer or from Lutron as GRX-CBL-
DMX-250/500.
GRX-4000 Series Control Unit
GP Panel
Circuit Selector in the GP Panel
To next panel
Typical Wiring: DMX to Link B (2Link
only)
Wires must be daisychained and capped off at
both ends of Link B.
DMX Cable Type
Belden 9729/89729:
Lutron GRX-CBL-DMX-250/500:
C
D
Common (Pin 1)
DMX+ (Pin 3)
DMX– (Pin 2)
Link B as DMX-512
NT-DMJ-IN-WH
Wire
(2) drain/shield
white
black
black
red
drain/shield
white
black
green
red
From
Circuit Selector
C
+
No Connect
No Connect
C
+
No Connect
No Connect
DMX Cable Wiring Table
To DMX Jack
(Pin #)
C (1)
+ (3)*
– (2)*
– (4)
+ (5)
C (1)
+ (3)*
– (2)*
– (4)
+ (5)
* Wire in daisy-chain configuration as follows: C to C, + to +, and to .