CARE & USE/INSTALLATION
|
19
PROSEAR™ 2 BURNER
It’s easy to keep your ProSear™ 2 burner operating at peak
performance. Just run it on “HI” with the hood open for 5
minutes after each use to burn away any food particles or
drippings.
Any ash accumulation on the burner screen can be re-
moved with a light brush or vacuum … BUT WAIT UNTIL
THE BURNER IS COOL!
Every 3 to 6 months, remove the burner and inspect the
venturi (inlet) and orifice to ensure that they’re free of ob-
structions.
Food debris on the inside of the burner can be gently
shaken out. Do not touch the ceramic surface.
When re-installing the ProSear™ 2 burner, be sure to
correctly position the burner.
CLEANING YOUR LYNX GRILL ...continued
BEFORE YOU CALL FOR SERVICE
Please check a few things before calling for service:
•Is there fuel supplied to the grill?
•Is the main shut-off valve open?
•Are you using the correct type of fuel? (LP or Natural Gas)
(See INDEX: “Gas Requirements” for further details.)
•Is your propane cylinder empty? Have you recently re-
filled the propane cylinder? If so, is the connection tight?
•Have you opened the valve on the propane cylinder?
•Is the grill plugged in to a live electric circuit?
If you’ve checked the above items, review the trouble-
shooting list below before calling for Lynx for service.
TROUBLESHOOTING YOUR LYNX GRILL
Heat Shield Removed,
Orice/Venturi Position
Inside View, Orice all
the way into venturi