CARE & USE/INSTALLATION
|
21
REPLACE any damaged supply lines.
•Check the Regulator
Make sure that the regulator & hose assembly is the one
designed for and supplied with your Lynx grill and that it
is correctly set up for the type of fuel you are using. (See
INDEX: “Regulator Conversion” for further details.)
The hose and regulator provided by Lynx must be used if
your grill is set-up for an LP Gas Cylinder.
Check that there is no physical pressure being applied to
the regulator attached to the back of the grill. The regulator
contains a flexible diaphragm and should not be allowed to
touch the grill body or its surroundings.
•Check for Obstructions
Ensure that the burners and drip tray are clean and free
from obstructions.
LP (Propane) units:
•Is the cylinder almost empty?
Almost-empty cylinders may not have sufficient pressure
to run the burners at high heat.
•Have the line pressure checked by a qualified technician
(See INDEX: “Gas Requirements” for further details.)
•Flow Limiting Device
Improper lighting procedures may have activated the LP
cylinder’s flow control device, reducing the heat output.
To reset the flow control:
•Shut off all burner controls and close the LP cylinder
valve.
•Wait 30 seconds and, very slowly, reopen the cylinder
valve.
•Wait a few seconds and relite a burner.
Bulk LP cylinder users:
Bulk LP cylinder lines must be properly regulated.
Ensure that you are using a 4/11 appliance regulator sup-
plied by Lynx and converted to LP gas. Also ensure that you
do not have more than one regulator in line.
Natural Gas units:
•Supply Line
Ensure that the supply line is at least 3/4” inside diameter
or 1” outside diameter.
•Check line pressure
Natural gas inlet pressure should be at least 7” W.C. and
manifold pressure not less that 4” W.C. under full load (with
all burners on.)
•Check burners for blockages.
•Check flame characteristics. (See INDEX: “Flame, Correct
Size” )
•Clean or adjust air shutter (See INDEX: “Air Shutter
Adjustment.”
WIND HITTING GRILL
Wind hitting the grill while in use, especially winds blowing
into or across the hood gap from behind, can cause poor
performance and in some cases can cause the control panel
to get dangerously hot.
Steady or gusty winds can prevent the normal exhaust of
hot gases. Locate your grill away from prevailing winds and
avoid grilling in windy conditions.
POTENTIAL PROBLEMS ...continued

Other manuals for Lynx L36PSR-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lynx L36PSR-2 and is the answer not in the manual?

Lynx L36PSR-2 Specifications

General IconGeneral
BrandLynx
ModelL36PSR-2
CategoryGrill
LanguageEnglish

Related product manuals