EasyManua.ls Logo

M/A-Com Orion - Page 51

M/A-Com Orion
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
Pressing and holding the
C (Scan Model) or c (System Model) button
for 2.5 seconds toggles the user into and out of the dynamic regroup group set.
A double beep will sound for entry or exit. The display will indicate
REGR_0x where "x" is a digit of 1 to 8 indicating the group when dynamic
regroups has been enabled by the user. If the radio is in dynamic regroup and
the user selects a group that has not been regrouped, the display will show NO
ENTRY. The radio will be prevented from transmitting and receiving calls in
this condition except for scanned groups.
Emergency Operation
If the pre-programmed group set on the currently selected system contains an
EMER/HOME group and the radio is in dynamic regroup, the radio will exit
dynamic regroup and declare the emergency on the HOME group. If no
EMER/HOME group is present, the radio will declare the emergency on the
currently selected dynamic regroup group.

Table of Contents

Other manuals for M/A-Com Orion

Related product manuals