214685 319 Revision A
Figure 9.5: Flow Control
10. Ensure flow control (A) is set to position 6.
11. Ensure feeder house variable speed is set to
MINIMUM.
CAUTION
Never start or move the machine until you are sure all
bystanders have cleared the area.
12. Start combine and run the machine slowly for 5 minutes
while watching and listening FROM THE OPERATOR’S
SEAT for binding or interfering parts.
NOTE:
Reel and side drapers will not operate until oil flow fills
the lines.
13. Run the machine at operating speed for 15 minutes.
Listen for any unusual sounds or abnormal vibration.
14. Perform run-up check as listed on Predelivery
Checklist, page 339 (yellow sheet attached to this
instruction) to ensure the machine is field-ready.
9.1 Performing Post Run-Up Adjustments
Stop engine and perform post run-up check as listed on the Predelivery Checklist (yellow sheet attached to this
instruction Predelivery Checklist, page 339) to ensure machine is field-ready.
WARNING
To avoid bodily injury or death from unexpected startup of machine, always stop engine and remove key
before making adjustments to machine.
Some adjustments may be necessary after the run-up. Refer to the following:
• 9.1.1 Adjusting Knife, page 320
• 9.1.2 Adjusting Knife Speed, page 321
RUNNING UP HEADER