EasyManua.ls Logo

MadMan EMS-3 - Technical Specifications; General Operating and Display Specs; Input Signal and Sender Specifications

MadMan EMS-3
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Madman EMS-3 Operating Manual Page 26
7 Specifications
Operating Temperature Range -10ºC to 60ºC (14ºF to 140ºF)
Storage Temperature Range -20ºC to 80ºC (-4ºF to 176ºF)
Humidity <85% non-condensing
Power Supply 8 to 30Vdc
Current Consumption
Approx. 85mA @ 13.8V (backlight highest setting), 35mA @13.8V
(backlight lowest setting)
Display
1.8” 160x128 pixel active matrix TFT display.
1000 cd/m2
Sunlight readable with anti-glare coating
LED Backlight can be set to automatic or can be manually adjusted
Alarm Outputs
2 Alarm outputs
Open collector transistor switch to ground
Maximum rating 0.25A (To drive an auto relay, piezo buzzer or LED)
ADC 12 bit
Dimensions See dimensional drawing below
Enclosure 2” (52mm) ABS, black in color, front mounting. Flame retardant.
Weight Approx. 110 grams (Instrument excluding cables)
Non-volatile memory storage 100000 write cycles
RPM Input
RPM input
Range: 0-99999 RPM.
Minimum signal for stable display: 5Vpp.
Fully A/C coupled, maximum voltage +/- 40V.
RF noise filter plus Schmitt trigger based input
EGT Thermocouple
Type K-type or J-type
Measurement range
K-Type: -100ºC to 1200ºC (-148ºF to 2192ºF)
J-Type: -100ºC to 1100ºC (-148ºF to 2012ºF)
Technology
Fully cold junction compensated using a precision internal temperature
reference and built in thermocouple linearization tables
Measurement accuracy
+/- 5 degrees typical over full temperature range, subject to quality of probe
used.
Inputs Differential, can use grounded and isolated probes
Common mode voltage range -2V to +3V
Analog Input Channels
Analog Input Channels 4 Channels with dipswitch programmable 1k pullup resistor
Pressure Sender Input
Pressure Sensors
Resistive Senders: The EMS-3 supports resistive type pressure
senders.
VDO Resistive Senders: The EMS-3 supports the VDO 2, 5 and 10
Bar senders. VDO pressure senders used to measure fuel pressure require
the fuel isolation kit available from VDO.
4-20mA Senders: The EMS-3 supports 4-20mA current output
pressure senders.
Voltage Output Pressure Senders: The EMS-3 supports voltage
output pressure senders.
SENDO Voltage Output Pressure Senders: The EMS-3
supports the SENDO MPS 2, 5, 7, and 10 bar senders.