EasyManua.ls Logo

MadMan EMS-3 - Coolant Level Detector Setup

MadMan EMS-3
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Madman EMS-3 Operating Manual Page 15
Low Alarm:
Enter the voltage threshold for when the low alarm must be activated. Any voltage below this value will activate the alarm.
Alarm:
Select which output the alarm must activate.
Cal:
Measure the battery voltage with a multimeter and then adjust this value to match that of the multimeters volts reading.
4.5 CLD (Coolant Level Detector) Setup
Display:
Select "ON" to enable the CLD display.
Switch Time:
The coolant level has a programmable switch time. This means that the level alarm from the coolant level switch must be
activated for at least the programmed time before an alarm is activated. This prevents false alarm messages when driving
over rough terrain etc.
Sensitivity:
Adjust the sensitivity to fine tune the trigger point.
Alarm:
Select which output the alarm must activate.