6.4 Commissioning
Do not run new or reconditioned engines during the first operating hours above 3/4 load. However, make
sure to vary the engine speed.
After this time period the engine can be slowly brought up to full power.
IMPORTANT!
Termination of liability for material defects by use of non-approved fluids and lubric
ants!
Liability of material defects is terminated if non-approved fluids and lubricants are used.
For this reason:
S Only use approved fluids and lubricants (see “Fluids and Lubricants ..." publication).
6.4.1 Filling Diesel Fuel
DANGER!
Risk of fire caused by diesel fuel!
Diesel fuel is highly flammable.
For this reason:
S No smoking and no open fires when handling fuels.
S Only refuel with engine off.
S Ensure cleanliness.
S Do not let fuel drip or leak out.
IMPORTANT!
Component damage to injection system caused by water in diesel fuel!
Absolutely prevent any ingress of water.
For this reason:
S Install a prefilter and a water separator into the fuel supply.
1. Fill diesel fuel according to the instructions of the manufacturer of the entire system.
2. Open fuel shutoff valve.