Operation
MAN Industrial Diesel Engines D2848/40/42 LE201/203/211/213
49
Carefully read the Operating Instructions before starting any work!
This is especially valid for the chapter on General Safety Instructions
and the safety instructions in each of the chapters.
7.4 Operation
7.4.1 Monitoring Operation
IMPORTANT!
Do not overload engine.
If faults occur, investigate and solve them immediately to prevent major damage from oc
curring!
The engine oil pressure is monitored during its operation.
If a fall in oil pressure is reported by the monitor, immediately shut down engine.
7.4.2 Stopping in an Emergency
An emergency-off button, for shutting down the system in an emergency, must be installed for each engine.