Maintenance and Care
MAN Industrial Diesel Engines D2848/40/42 LE201/203/211/213
70
Carefully read the Operating Instructions before starting any work!
This is especially valid for the chapter on General Safety Instructions
and the safety instructions in each of the chapters.
Crankshaft - Coolant pump - Tensioner pulley
1. Loosen mounting bolt (1).
2. Turn adjustment screw (2) clockwise until belt
has the correct tension
3 Retighten mounting nuts (1)
To change the belt, turn adjustment screw (2)
counter clockwise.
1
2
1