V.033114
M&R Companies 1N 372 Main St. Glen Ellyn, IL 60137 USA 35
Tel: +630-858-6101 Fax: +630-858-6134 www.mrprint.com | store.mrprint.com
This menu item is used to control the preheat time
for the Quartz Flash panels used on your system.
Press the data entry cell to the right of Preheat; a
numeric keypad is displayed. Enter the Preheat
time in seconds and then press Enter. The
maximum Preheat time is 15 seconds, the
minimum is 0 seconds.
A graduated scale provides a visual indicator of
the balance of Preheat Time. If the Preheat Time
is set for 15 seconds, the graduated scale will then
display a solid green line up to the 15 indicator. As
the Preheat Time counts down, the green line will
retract towards the zero indication and the data
entry cell will display the remaining Preheat Time.
WARNING: When using the Preheat function, be
sure that the pallets are not located under the
flash unit heating elements. The infrared heat
produced during the preheat cycle can damage
substrates and/or pallets.
The Glue menu is used to adjust the operation of
the optional M&R Annamister Automatic Adhesive
Application System. From the Options menu,
press the Glue button.
Spray 1
Revolution (1)
Spray Every (2)
Spray 1 Revolution permits the operator to apply
adhesive to all pallets during one complete
revolution of all pallets. To activate or deactivate
this control feature, press the Off button to the
right of Spray 1 Revolution. The button changes
to On.
Spray Every allows the operator to program the
M&R Annamister to apply adhesive to the pallets
based on the number of index revolutions. If the
indication in the data entry cell is set to 0, the M&R
Annamister system is deactivated.
If the indication is set to 1 the M&R Annamister
applies adhesive to all pallets regardless of the
cycle or revolution number. If the indication is set
to 2, the M&R Annamister applies adhesive to all
pallets on every other revolution. The maximum
setting is 99. To enter a number for the revolutions
for Spray Every, press the data entry cell to the