V.033114
42 M&R Companies 1N 372 Main St. Glen Ellyn, IL 60137 USA
Tel: +630-858-6101 Fax: +630-858-6134 www.mrprint.com | store.mrprint.com
Double Index
Fork Proximity
Switch
The Double Index Fork Proximity switch is
mounted to the index base near the load and
unload stations and is positioned so that it reads
the double index fork when the double index fork
is retracted.
When the Double Index proximity switch reads
the double index fork, the indicator changes to red.
This confirms the operation of the Double Index
proximity switch.
If the indicator does not change to red when this
proximity switch is reading the Double Index fork,
then the operation of the proximity switch and/or
the cables may be faulty. Inspect and/or replace
the proximity switch and/or cables to correct the
problem.
Home Post
Proximity
Switch
The Home Post proximity switch is used during
the initial installation and setup of your press, or
when ever the servo drive assembly or
components have been replaced. This proximity
switch is not used during normal operation. The
switch is located on the left side of the index drive
assembly.
When the Home Post proximity switch reads the
index drive assembly, the indicator changes to
red. This confirms the correct operation of the
Home Post proximity switch.
If the indicator does not change to red when this
proximity switch is reading the Index drive
assembly, then the operation of the proximity
switch and/or the cables may be faulty. Inspect
and/or replace the proximity switch and/or cables
to correct the problem.
To access the OTHER TESTS press the OTHER
TESTS button on the HARDWARE TEST menu
screen.
The OTHER TESTS menu displays control
elements such as Emergency Relay, T-Shirt
Sensor, Air Pressure and HEAD PRINT
BUTTONS. To the right of the control elements
are indicators which display either OFF or ON. As
each of the control elements is activated the
indicator to the right displays an ON indication.
This confirms the operation of the control element.
For example, if you disconnect the Yellow Cycle
Interruption cords, the indicator to the right of
Yellow Cord displays an OFF indication.
Press the Tests button to return to the