WARNING: To prevent possible injury to personnel and/or damage to the equipment, lock out and tag the
electrical service and compressed air supply to the equipment.
Lubricate Micro-Registration Threaded Shafts
1 - Permatex Super Lube with Teflon Grease
(M&R Part No. 7018034)
1 - Small Brush
1 – Towel
1. Use a towel to remove old grease from the threaded shaft
surfaces.
2. Loosen micro-registration knobs (1).
3. Turn adjustment knob (2) counterclockwise as far as
possible.
4. Use a small brush to apply a thin coat of grease to the
exposed threads (3).
5. Return adjustment knob (2) to original position.
6. Tighten micro-registration knob (1).
7. Repeat procedure for each print head.