DIAGNOSTICS
Press the Checkmark with Diagnostics highlighted to
enter screens where you can run diagnostics on the
control board, sensors and switches.
Control Board
Self Check
Enable Relays
Exit
Temperature Sensors
T1 Thermistor Temperature
T2 Thermistor Temperature
T3 Thermistor Temperature
T4 Thermistor Temperature
Exit
Inputs
Curtain Switch 1 Closed/Open
Curtain Switch 2 Closed/Open
LPCO Switch Closed/Open
HPCO Switch Closed/Open
Bin Level - Low (Optional Bin Level Probe) Closed/
Open
Bin Level - Medium (Optional Bin Level Probe)
Closed/Open
Bin Level - High (Optional Bin Level Probe)
Closed/Open
Sensing Ice No/Yes
Water Level Low No/Yes
Water Level High No/Yes
Exit