3.
Place ready the new canister (1) filled with cleaning
agent.
Feed the (red) supply tube plus suction nozzle (2) into
the full canister (1) and screw it on.
Make sure that there are no kinks in the tube and that
the vent hole on the canister cap is unobstructed.
4.
Check the position of the canisters:
The surface on which the canisters sit must not lie
above the level at which the appliance feet meet the
appliance case.
The surface on which the canisters sit must not lie
more than 1 metre below this level.
Check that you have connected the tube to the correct
connector.
The cleaning agent must be attached to appliance
connector G.
(The colour red is used throughout.)
5 Cleaning procedures