46 Part Number 020002365 08/25/2015
Troubleshooting Section 5
Error Notes
Error codes will interrupt the temperature display and
stay active until the error is corrected.
If multiple errors are present, the errors will rotate and
display every 5 seconds.
Resetting errors — After correcting the problem, the
respective switch for the error must be cycled OFF and
then ON to reset.
Disconnecting and reconnecting power will erase all
errors.
Error Code Error Cause
E1 Low Water Supply Pressure Lower than 5 psi for 5 Seconds
E2 Low CO
2
Pressure Lower than 10 psi for 5 Seconds
E3 Low Water Level – Water Bath Must Cover Top of Evaporator - Water Level Probe
Mounted Too High
E4 High Water Bath Temperature Water Bath Temperature Greater Than 45°F
E5 High Water Supply Pressure Water Pressure Greater than 75 psi
E6 High Refrigeration Temperature Discharge Line Temperature Greater than 190°F
E7 High Ice Bank Size Ice Contacting Center Ice Bank Probe
E8 Long Carb A Run Time Energized for 7 Continuous Minutes
E9 Long Carb B Run Time Energized for 7 Continuous Minutes

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Multiplex 50GAX04 and is the answer not in the manual?

Manitowoc Multiplex 50GAX04 Specifications

General IconGeneral
BrandManitowoc
ModelMultiplex 50GAX04
CategoryChiller
LanguageEnglish

Related product manuals