–15–
REFRIGERATION SYSTEM INSTALLATION
Usage With Non-Manitowoc Condensing Units
Manitowoc CVD
®
Condensing Units are specifically
designed for usage with a QuietQube
®
Ice Machine
Head Section. Standard condensing units will not
operate a QuietQube
®
Ice Machine Head Section.
QuietQube
®
Ice
Machine
CVD
®
Condensing
Unit
Line Set
Q1000C
SU1000C/ UC-300
Q1400C
CVD1075
CVD1475
CVD1476
RC-20
RC-30
RC-50
Q0600C
Q0800C
CVD0675
CVD0875
RC-21
RC-31
RC-51
QDUAL
CVD1875
CVD2075
RC-22
RC-32
RC-52
Line Set
Suction
Line
Liquid
Line
Insulation
Thickness
RC 20/30/50
3/4 in.
(19.1 mm)
1/2in.
(12.7 mm)
Suction
Line
1/2"
(13 mm)
Liquid Line
1/4" (7 mm)
RC 21/31/51
5/8 in.
(15.9 mm)
3/8 in.
(9.5 mm)
RC 22/32/52
7/8 in.
(22.2 mm)
5/8 in.
(15.9 mm)
Suction
Line
3/4"
(19 mm)
Liquid Line
1/4" (7 mm)