–64–
CVD1476 WATER COOLED CONDENSING UNIT
Place the ice machine toggle switch into the OFF
position.
1. "Front seat" (shut off) the receiver service valve.
Hang a tag on the switch as a reminder to open the
valve before restarting.
2. Perform steps 1-6 under "Q1400C Head Section".
3. Insert a large screwdriver between the bottom
spring coils of the water regulating valve. Pry
upward to open the valve.
4. Hold the valve open and blow compressed air
through the condenser until no water remains.
AuCS
®
ACCESSORY
Refer to the AuCS
®
Accessory manual for
Winterization of the AuCS
®
Accessory.