4. Disassemble for cleaning.
A. Twist both of the inner tube ends until the tabs
line up with the keyways.
B. Pull the inner tube ends outward.
SV1211
WATER DISTRIBUTION TUBE DISASSEMBLY
INNER
TUBE
INNER
TUBE
KEYWAY
TAB