SR6001 RS-232C Control Specification Page: 14 / 19
Document Version [1.00]
Company Restricted
Command Reply from Slave
VALUE “MSV:0xxx”
UP “MSV:1”
Multi RoomA
Speaker
VOLUME
DOWN “MSV:2”
“MSV:xxx”
xxx = Vol. value as +90 ~-90
VARIABLE “MSS:1”
Multi RoomA
Speaker
VOLUME SET
FIXED “MSS:2”
“MSS:1” ( VARIABLE)
“MSS:2” (FIXED)
TOGGLE “MSM:0”
OFF “MSM:1
Multi RoomA
Speaker
AUDIO MUTE
ON “MSM:2
“MSM:1”,
“MSM:2”
5-2. Specific Commands
Command from Host Reply from Slave
Auto status feedback
(The product default is disabled
all auto status feedback.)
“AST:x” (x = ‘0’ ~ ’F’)
bit 3 : Layer 4 ( 1 = Enable, 0 = Disable)
bit 2 : Layer 3 ( 1 = Enable, 0 = Disable)
bit 1 : Layer 2 ( 1 = Enable, 0 = Disable)
bit 0 : Layer 1 ( 1 = Enable, 0 = Disable)