4.3 STARTING THE GENERATOR
Before starting the generator check that all the doors
is closed.
Before starting the generator ensure that all the preliminary
checks have been carried out.
Starting
Proceed with starting by pressing the ON button
(ref.4),You will note that all the LEDs come on while a
self-test of about 5 seconds is being run.
When the test has been completed, the panel power
LED (ref.5) will remain on.
Start the generator by pressing the START button (ref.3)
and release it only when the generator has started.
Do not exceed 5 seconds for each starting attempt.
Proper functioning of the generator will be signalled by
the generator functioning LED coming on (ref.6). When
the above operations are carried out, the generator
safety switches are automatically activated
(see the chap 5 on “Safety switches”).
Repeated unsuccessful starting attempts may cause
excessive accumulation of water in the exhaust
system with possible serious damage
to the engine.
In case of have difficulty in starting the engine,
absolutely do not persist for a long time before first
having closed the seawater intake cock (Ref.10).
Do not make more than 5 consecutive starting
attempts as you may damage the starter motor.
During the running-in period (the first 50 hours), do
not apply loads exceeding 70% of the rated power
of the generator.
For more detailed information, consult the manual
provided by the engine manufacturer, which
accompanies each generator.
4.4 STOPPING THE GENERATOR
Stop the generator by pressing the STOP button on
the control panel (ref.11).
Before stopping the generator, it is
advisable to run it for a few minutes without
drawing current in order to allow gradual cooling
of the engine and the alternator.