EasyManua.ls Logo

Massimo MSU 600 - TROUBLE CODE LIST (500 cc)

Massimo MSU 600
103 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TROUBLE CODE LIST500cc
No Code Instruction
1 P0030
OXYGEN SENSOR HEA TING CONTROL
CIRCUITOPEN CIRCUIT
2 P0031
OXYGEN SENSOR HEATING CONTROL
CIRCUITSHORT TO GOUND
3 P0032
OXYGEN SENSOR HEA TING CONTROL
CIRCUITSHORT CIRCUIT TO POWER
4 P0053
OXYGEN SENSOR HEA TING INTERNAL
RESISTANCE UNREASONABLE
5 P0105
INLE T PRESSURE SENSOR SIGNAL NO CHANGE
ICE UP
6 P0106 INLE T PRESSURE SENSOR UNREASONABLE
7 P0107 INLE T PRESSURE SENSOR UNREASONABLE
8 P0108
INLE T PRESSURE SENSOR SHORT CIRCUIT TO
POWER
9 P0112
INLE T AIR TEMPERATURE SENSOR SIGNAL
VOLTAGE TOO LOW
10 P0113
INLE T AIR TEMPERATURE SENSOR SIGNAL
VOLTAGE TOO HIGH
11 P0116
ENIGNE COOLANT TEMPERATURE S ENSOR
UNREASONA BLE
12 P0117
ENIGNE COOLANT TEMPERATURE S ENSOR C
IRCUIT VOLTAGE TOO LOW
13 P0118
ENIGNE COOLANT TEMPERATURE S ENSOR C
IRCUIT VOLTAGE TOO H IGH
No Code Instruction
14 P0122
THROTTLE POSITION S ENSOR CIRCUIT
VOLTAGE UNDER LIMINAL VALUE
15 P0123
THROTTLE POSITION S ENSOR CIRCUIT
VOLTAGE EXCEED L IMINAL VALUE
16 P0130 OXYGEN SENSOR SIGNAL UNREASONA BLE
17 P0131
OXYGEN SENSOR SIGNAL CIRCUIT
VOLTAGETOO LOW
18 P0132
OXYGEN SENSOR SIGNAL CIRCUIT
VOLTAGETOO HIGH
19 P0134 OXYGEN SENSOR CIRCUIT SIGNAL TROUBLE
20 P0201
1 CY LINDER OIL ATOMIZER CONTROL CIRCUIT
OPE N CIRCUIT
21 P0261
1 CY LINDER OIL ATOMIZER CONTROL CIRCUIT
S HORT CIRCUIT TO GOUND
22 P0262
1 CY LINDER OIL ATOMIZER CONTROL CIRCUIT
S HORT CIRCUIT TO POWER
23 P0321
TRANSIENT SPEED S IGNAL REFERENCE POINT
TROUBL
24 P0322
NO TRIGGER(VEHICLE S PEED) PULSE SIGNAL
(OPEN CIRCUIT OR SHORT CIRCUIT)
25 P0501
VEHICLE SPEED SENSOR SIGNAL
UNREASONAB LE
26 P0506
IDLE SP EED CONTROL ROTATING SPEED
LOWER THAN TARGET IDLE SPEED
94