11 12
DIGITAL CLAMP METER DIGITAL CLAMP METER
CORRECT
INCORRECT
5.2DC Voltage (DCV) measurement
Maximum input voltage of DC voltage (DCV) is
600VDC. DC voltage higher than 600Vdc is not
allowed for measurement to prevent electrical
shock and / or damage the meter.
WARNING
• Turn the rotary switch to 600V .
• Connect black test lead and red test lead to COM input
socket and V input socket separately.
• Use the other two ends of test leads to measure the
voltage of circuit to be measured. (Connect with the
circuit to be measured in parallel)
• The measurement current value can be read through
the LCD display.