19 20
measurement units at the right side of the display
(mA or A). When only the figure "1" displayed, it
indicates overrange situation and the higher range
has to be selected.
6. Turn off the power of the measured circuit and
discharge all the high voltage capacitors. Remove
the test leads and recover the measured circuit.
4. Technical Specifications
4.1 General Specifications
Environment conditions:
1000V CAT. II and 600V CAT.III
Pollution degree: 2
Altitude < 2000m
Operating temperature:
0~40°C, 32°F~122°F(<80% RH, <10°C noncondensing)
Storage temperature:
-10~60 °C, 14°F~140°F(<70% RH, battery removed)
Temperature Coefficient:
0.1(specified accuracy) /°C(<18°C or >28°C)
MAX. Voltage between terminals and earth ground:
750V AC rms or 1000V DC.
Fuse Protection: mA: Resettable fuse (F200mA/250V)
Sample Rate: 3 times/sec for digital data.
Display: 4 1/2 digits LCD display. Automatic indication
of functions and symbols.
Over Range indication: LCD will display "1".
Low battery indication:
The " " is displayed when the battery is under the
proper operation range.
Polarity indication: " " displayed automatically.
Power source: 9V
Battery type: NEDA 1604, 6F22, or 006P.
Dimensions: 195(L)92(W)55(H) mm.
Weight: 380g. Approx. (battery included).
Accuracy is specified for one year after calibration, at
operating temperatures of 18°C to 28 C, with relative
humidity at 0% to 75%.
Accuracy specifications take the form of:
±(% of Reading + Number of Least Significant Digits)
°
4.2 Measurement specifications
4.2.1 DC Voltage
Resolution
Range
0.01mV
Accuracy
±(0.1% of rdg +5 digit)
200mV
0.1mV
1mV
10mV
0.1V
2V
20V
200V
1000V
±(0.15% of rdg +5 digits)
4.2.2AC Voltage
Resolution
Range
Accuracy(50~60Hz)
±(0.8% of rdg +15 digits)
0.1mV
1mV
10mV
0.1V
2V
20V
200V
750V
±(1.0% of rdg +15 digits)
Input impedance: 10M
Max. input voltage: 250Vdc or ac rms for 200mV range
and 1000Vdc or 750V ac rms for other ranges,
±(0.05% of rdg +5 digit)
±(0.5% of rdg +15 digits)
Resolution
Range
Accuracy(40~400Hz)
±(1.0% of rdg +50 digits)
0.1mV
1mV
10mV
0.1V
2V
20V
200V
750V
±(1.2% of rdg +50 digits)
±(1.0% of rdg +15 digits)