8.4 ERROR TROUBLESHOOTING - 0140 / 01B2
ERROR CODE 0140 or 01B2
1) SYMPTOM:
a. 0140 - Incline motor operation has failed.
b. 01B2 - The incline motor has no action or current.
2) SOLUTION:
a. Run Auto Calibration (see Section 4.8), then check the LCB LEDs. If the incline LED is not a solid light (only one LED will show a solid
light at a time), replace the LCB (Figure A).
b. If the LCB incline LEDs are solid, use a multi meter to check the fuses. They should have an ohm reading of 0 (Figures B & C).
c. If the LCB incline LEDs are solid, and the fuses check out ok, run auto calibration.
- If calibration fails, replace the incline motor.
FIGURE A
FIGURE B
FIGURE C