EasyManua.ls Logo

Matrix r7xi-02 - Error Code Troubleshooting

Matrix r7xi-02
166 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
64
CHAPTER 8: TROUBLESHOOTING
8.4 TROUBLESHOOTING - ERROR 04A0 / 0440
FIGURE A FIGURE B
ERROR CODE 04A0 / 0440
1) SYMPTOM:
04A0 – UCB communication disconnected.
0440 – Timeout receive packet (LCB can not receive any data for 50 seconds).
2) SOLUTION:
If the display is giving a 04A0 error, check the LCB LED10 status.
- LED10 blinking: Turn off power and after 3 seconds, turn on power again. If console also show the 04A0, re-install UCB software again. If
this does not resolve the issue, replace the UCB.
- LED10 off: Check the connection of the digital communication wire at the UCB and LCB (Figures A & B). If the connection is good,
replace the digital communication wire.
- If replacing the UCB and digital communication wire does not work, replace the LCB.

Table of Contents

Related product manuals