93
9.7 HEART RATE GRIPS REPLACEMENT
CHAPTER 9: PART REPLACEMENT GUIDE
1) Remove the 3 screws holding the HR grip together (Figure A).
2) Once the 3 screws are removed, the HR grip can be split into 2 pieces (Figure B).
3) Disconnect the keypad / overlay and the HR plate wiring and remove the old HR grip (Figure C).
4) Reverse Steps 1-3 to install new HR grips. The white wire should be on the back side HR plate, the red wire on the front (Figure D).
5) Test the Bike for function as outlined in Section 9.26.
FIGURE A FIGURE B
FIGURE C
FIGURE D