P-Series User Manual Rev2022 14
Specications
P001 SPECIFICATIONS
Flow Range 0.005 to 200 cc/min
Accuracy (3 cP) ± 0.2% of reading over a 200:1 range
Maximum Operating Pressure 7250 psi (500 bar)
Weight 1.1 kg
Recommended Filtration 5 micron
Port Size(s) 1/4 inch or 6 mm tube tting
Fluids Most non-aqueous, hydrocarbon based uids
MATERIALS OF CONSTRUCTION
External Stainless steel, type 316
Wetted Stainless steel, type 316, 440C; Silicon Nitride;
Nickel Based Carbide
O-Rings Standard: Viton®
Optional: Peruoroelastmer
FREQUENCY TRANSMITTER
Output Signal Standard:
5 Vdc, single phase
Optional: Quadrature 5 Vdc, two phase
Current sinking, 20 mA max., single phase
K-Factor
Single Phase: 12,000 pulses/cc
Two Phase:
24,000 pulses/cc, 4x decoded
(6,000 pulses/cc/phase, 1x decoded)
Power Supply Requirements 5-26 Vdc @ 30ma
Ambient Operational Range -40°C to 80°C, Single piece - Two piece to 110°C
Metered Liquid Temp Range -40°C to 90°C, Standard model
(based on 20° ambient)
-40°C to 155°C, Two piece, high temperature model
-40°C to 225°C, Two piece, ultra high temperature model
Compliance CE Certied, Ex-proof version available with ATEX/IECEx II 2 G Ex
db IIB Tx Gb as well as UL, cUL certication for Class 1, Division 1,
Groups C and D, Tx
ANALOG TRANSMITTER
Output Signal Any range of ± 10V or ± 20mA linearized and damped
with anti-dither protection
Power Supply Requirements 12Vdc @ 90 mA, 24Vdc @ 45 mA
Ambient Operational Range -40°C to 80°C, Single piece - Two piece to 110°C
Metered Liquid Temp Range -40°C to 90°C, Standard model
(based on 20° ambient)
-40°C to 155°C, Two piece, high temperature model
-40°C to 225°C, Two piece, ultra high temperature model
Compliance CE Certied, Ex-proof version available with ATEX/IECEx II 2 G Ex
db IIB Tx Gb as well as UL, cUL certication for Class 1, Division 1,
Groups C and D, Tx