23
i-32V5
TABLE 2. JOINT OPERATION, BRACKET 1
INTERVENTION ORDER
STATUS OPERATION r10 r15 r12 r16 r23 r24
4
1) Heat pump
2) Aer r12 minutes, boiler
3) Aer further r12 minutes, plant inte-
HEAT /
HEAT+SAN
HEAT 1 0/1/2
Set the min-
utes
/ 4/6 1/3
5
1) Heat pump
2) Aer r16 minutes,
heater
HEAT+SAN DHW 0/1 1 /
Set the
minutes
0/1/4 2/3
6
1) Heat pump
2) Aer r16 minutes, boiler
HEAT+SAN/ DHW 0/1 0/1/2 /
Set the
minutes
2/3/5/6 2/3
7
1) Heat pump
2) Aer r16 minutes,
heater
3) Aer further r16 minutes, boiler
HEAT+SAN DHW 0/1 1 /
Set the
minutes
2/3 2/3
8
1) Heat pump
2) Aer r16 minutes, boiler
3) Aer further r16 minutes, DHW inte-
HEAT+SAN DHW 0/1 1 /
Set the
minutes
5/6 2/3
9
1) Heat pump
2) Aer r12 minutes, plant/DHW inte-
HEAT /
HEAT+SAN
HEAT/DHW 1 1
Set the min-
utes
Set the
minutesi
0 3
10
1) Heat pump
2) Aer r12 minutes, boiler
HEAT /
HEAT+SAN
HEAT/DHW 0/1 0/1/2
Set the min-
utes
Set the
minutes
3/6 0
11
1) Heat pump
2) Aer r12 minutes, plant/DHW inte-
3) Aer further r12 minutes, boiler
HEAT /
HEAT+SAN
HEAT/DHW 1 1
Set the min-
utes
Set the
minutes
3 3
12
1) Heat pump
2) Aer r12 minutes, boiler
3) Aer further r12 minutes, plant/
HEAT /
HEAT+SAN
HEAT/DHW 1 1
Set the min-
utes
Set the
minutes
6 3
TABLE 3. JOINT OPERATION, BRACKET 2
ORDINE INTERVENTO
STATUS OPERATION r10 r15 r12 r16 r23 r24
1
1) Boiler
2) Aer r12 minutes, heat pump
HEAT /
HEAT+SAN
HEAT 0/1 0/1/2
Set the min-
utes
/ 1/3/4/6 0/2
2
1) Boiler
2) Aer r12 minutes,
heater
3) Aer further r12 minutes, heat pump
HEAT /
HEAT+SAN
HEAT 1 0/1/2
Set the min-
utes
/ 1/3 1/3
3
1) Boiler
2) Aer r12 minutes, heat pump
3) Aer further r12 minutes, plant inte-
HEAT /
HEAT+SAN
HEAT 1 0/1/2
Set the min-
utes
/ 4/6 1/3
4
1)
2) Aer r12 minutes, heat pump
HEAT /
HEAT+SAN
HEAT 1 0/1/2
Set the min-
utes
/ 0/2/5 1/3
5
1) Boiler
2) Aer r16 minutes, heat pump
HEAT+SAN DHW 0/1 0/1/2 /
Set the min-
utes
2/3/5/6 0/1
6
1) Boiler
2) Aer r16 minutes,
heater
3) Aer further r16 minutes, heat pump
HEAT+SAN DHW 0/1 1 /
Set the min-
utes
2/3 2/3
7
1) Boiler
2) Aer r16 minutes, heat pump
3) Aer further r16 minutes, DHW inte-
HEAT+SAN DHW 0/1 1 /
Set the min-
utes
5/6 2/3
8
1)
2) Aer r16 minutes, heat pump
HEAT+SAN DHW 0/1 1 /
Set the min-
utes
0/1/4 2/3
9
1) Boiler
2) Aer r12 minutes, heat pump
HEAT /
HEAT+SAN
HEAT/DHW 1 1
Set the min-
utes
Set the min-
utes
3/6 0
10
1) Boiler
2) Aer r12 minutes, plant/DHW inte-
3) Aer further r12 minutes, heat pump
HEAT /
HEAT+SAN
HEAT/DHW 1 1
Set the min-
utes
Set the min-
utes
3 3
11
1) Boiler
2) Aer r12 minutes, heat pump
3) Aer further r12 minutes, plant/
HEAT /
HEAT+SAN
HEAT / SANITARIO 1 1
Set the min-
utes
Set the min-
utes
6 3