TABLE 6. INTEGRATION HEATERS OPERATION
 STATUS OPERATION PLANT INTEGRATION HEATER DHW INTEGRATION HEATER
2 HEAT+SAN DHW
Only if all 3 of the following condions are met:
-the output is congured for Plant integraon
heater;
-r24=1/3;
-plant water temperature remote probe pres-
;
the plant integraon heater is acvated in the
following situaons:
- r12 minutes aer the start of its count ac-
vated in “HEAT” mode previously running (see
line 1);
- if its count is not already acvated in the pre-
vious “HEAT” mode, r12 minutes aer the tem-
perature control demand.
- In SANITARY mode, with remote probe not
congured, the plant integraon heater is de-
acvated or any of its counts are interrupted.
- With “remote on-o” contact open, the Plant
integraon heater is deacvated.
Works as indicated in TABLES 1,2,3 and 4.
3 COOL+SAN DHW Cannot be acvated Works as indicated in TABLE 5.
4 COOL+SAN COOL Cannot be acvated Cannot be acvated
AUXILIARY SYSTEMS OFFSET MANAGEMENT


r29G02
r30G05
r31G03
G02G03G05

WARNINGS
notone
PLANT SEASON



 Value 
DO7 can be acvated via H85 31 Plant season warning
ALARM

I/O Resource Parameter Value 
DO7 can be acvated via H85 24 Alarm warning
MACHINE BLOCK

I/O Resource Parameter Value 
DO7 can be acvated via H85 47 Alarm warning
DEFROST

I/O Resource Parameter Value 
DO7 can be acvated via H85 21 Defrost in progress warning